PoE Cable and Voltage Drop Calculator

Find out whether a Power over Ethernet run will actually deliver the power a camera needs. Enter the PoE standard, cable construction and length to get the voltage at the device, the power lost in the cable and the maximum usable distance for that load.

Cable and power parameters

Result at the camera

0V at the camera

against a 0 V minimum for this standard

Loop resistance0 Ω
Cable current0 A
Power lost in the cable0 W
Power drawn at the switch0 W
Usable length for this load0 m
Ethernet channel limit100 m

Adjust the inputs

How the calculation works

Power over Ethernet is a direct-current circuit. The switch pushes current down the cable, thecable’s own resistance turns part of that into heat, and the camera receives whatever is left. Thelonger the run, the more is lost — and because the camera is a constant-power load, the losscompounds: as voltage falls the current rises, which increases the loss further. That feedback iswhy PoE runs fail abruptly rather than degrading gently.

Stage Formula Example — 802.3at, Cat5e copper, 80 m, 25 °C
Conductor resistance catalogue value × temperature coefficient 0.0956 Ω/m
Loop resistance 2 × conductor × length ÷ pairs in parallel 15.30 Ω
Cable current solved from V·I − I²R = P 0.255 A
Voltage at the camera VPSE − I·R 49.1 V
Power lost in the cable I²R 0.99 W
Power drawn at the switch VPSE × I 13.49 W

Why the voltage column matters more than the wattage. A camera rated at 12.5 Wwill not simply run slower at 40 V — below its minimum input voltage it reboots in a loop, orfails to start at all, and the fault usually appears only on the longest run on the site. Alwayscheck the camera’s minimum input voltage against the figure above, not against the switch’s rating.

Maximum run length by cable and standard

The table below gives the longest cable that still delivers the full rated power of each PoEstandard, assuming a 53 V switch output at 20 °C. Values above 100 m are shown as100+ because the Ethernet channel limit binds first.

Cable PoE12.95 W PoE+25.5 W PoE++ Type 351 W PoE++ Type 471.3 W
Cat5e · 24 AWG · CCA 97 37 37 29
Cat5e · 24 AWG · solid Cu 100+ 93 93 73
Cat6 · 23 AWG · solid Cu 100+ 100+ 100+ 98
Cat6A · 23 AWG · solid Cu 100+ 100+ 100+ 98
Cat6A · 22 AWG · solid Cu 100+ 100+ 100+ 100+

Two things stand out. First, Type 4 power is short-range: a 71 W device onCat6A runs out of usable cable around 73 m, well inside the 100 m the standard allows fordata. Second, CCA cable roughly halves every one of those distances — and it isthe single most common cause of intermittent PoE faults on real installations.

The table shows the voltage limit. The switch port has a separate power budget —15.4 W, 30 W, 60 W or 90 W — which the calculator above reports asPower drawn at the switch and which can bind first on a heavily loaded port.

The CCA trap

Copper-clad aluminium is exactly what the name says: an aluminium core with a thin copper skin.Aluminium conducts at roughly 61% of copper, so a CCA conductor has about 2.5 times the resistance ofthe solid-copper equivalent. On a short data-only run it works well enough to pass a cable tester,which is why it ends up on sites at all. On a PoE run it behaves quite differently.

  • It reaches the voltage limit far sooner. The table above shows Cat5e CCA failing802.3at around 37 m, against 93 m for solid copper. If your longest camera run is 50 m,the cable type decides whether the project works.
  • It gets worse as it warms. Resistance rises with temperature, and a bundled CCArun carrying current warms up more than copper does. Set the temperature field above to 50 °Cand watch the usable length fall.
  • The failure is intermittent, not total. A CCA run that is marginal may work inwinter and fail in summer, or work until a second camera on the same bundle powers up.

If a PoE device is rebooting at night, drawing a 40–60 m run, or failing only on warmdays, check the cable’s conductor material before you replace the camera.

What to do when the run is too long

  • Move to a thicker conductor first. Cat6A at 22 AWG buys roughly 25% moredistance than Cat5e at 24 AWG for the same power, and costs far less than changing the topology.
  • Use all four pairs. If the device supports 802.3bt Type 3 or Type 4, currentsplits across four pairs instead of two and the loop resistance halves. That is already accounted forin the table above.
  • Add a PoE extender mid-run. A midspan extender re-powers the second leg, whichcosts one extra switch port and gives another 100 m. Cheaper than trenching.
  • Run fibre and power locally. Beyond about 150 m, a fibre link plus a localPoE injector is the only arrangement that is both reliable and serviceable.

Frequently asked questions

How far can I run PoE cable?

For 802.3af and 802.3at the answer is normally the 100 m Ethernet channel limit, not the power limit. 802.3at on solid-copper Cat5e reaches its voltage limit at about 93 m, so a 100 m run is already marginal. Higher-power 802.3bt Type 4 devices are the exception: a 71 W load exhausts the cable at roughly 73 m on Cat6A and far sooner on thinner or CCA cable.

Why does my PoE camera reboot at night or in hot weather?

Almost always a voltage-margin problem rather than a camera fault. Cable resistance rises with temperature, so a run that sits just inside its limit in winter can fall below the camera’s minimum input voltage on a warm day. Infra-red illumination also draws more current at night, which increases the drop further. Both effects push the same run over the edge at the same time.

Does CCA cable really matter for PoE?

Yes, and more than almost any other cable variable. Copper-clad aluminium has roughly 2.5 times the resistance of solid copper, which cuts the usable PoE distance by more than half. On a 50 m run that is often the difference between a working installation and one that needs a midspan extender. If a PoE fault is intermittent and the run is over 35 m, check the conductor material first.

What is the maximum power PoE can deliver?

802.3bt Type 4 delivers 90 W at the switch port and guarantees 71.3 W at the device, which covers most PTZ cameras with heaters and wipers. The catch is distance: Type 4 uses all four pairs and still runs out of cable well before 100 m, so high-power devices usually need Cat6A and a short run, or a local power supply.

Can I just raise the switch voltage to compensate?

Only within the standard’s range, and it buys very little. 802.3at permits 50–57 V at the port, so moving from 53 V to 57 V recovers only a few metres. The voltage drop is set by current multiplied by resistance, and the current is set by the load, so the effective lever is cable resistance — a thicker conductor or a shorter run — not the supply voltage.

Embed this calculator on your site

Integrators, consultants and industry publications are welcome to embed this tool. Copy the code below — it stays in sync with our latest version automatically.

<iframe src="https://iufuture.com/tools/poe-cable-calculator/?iu_embed=1" width="100%" height="760"
        style="border:1px solid #e2e8f0;border-radius:10px;max-width:100%"
        loading="lazy" title="PoE Cable and Voltage Drop Calculator by IUFUTURE"></iframe>
<p><a href="https://iufuture.com/tools/poe-cable-calculator/">PoE Cable and Voltage Drop Calculator</a> by IUFUTURE</p>

Related IUFUTURE Products

Browse Product Categories

Security Cameras  |  Video Doorbells  |  Video Intercoms  |  Intercom Accessories

More Resources

CCTV Lens and Field of View Calculator  |  Camera Coverage and Count Planner  |  IP Camera Bandwidth Calculator  |  B2B Security Solutions  |  Get a Quote